Differences

This shows you the differences between two versions of the page.

Link to this comparison view

Next revision
Previous revision
Next revision Both sides next revision
ansys [2011/07/15 11:50]
jclifford created
ansys [2017/07/26 09:27]
nsampo
Line 1: Line 1:
-====== ANSYS 13.0 ====== +====== ANSYS 18  ​====== 
-Due to the size of the installation,​ please DO NOT attempt to install this application via a wireless or VPN network connection. ​ Prior to installing any new version or upgrade, please ensure that you are connected to a live, wired, Ethernet jack on campus and that your wireless network interface is disabled. You will need to uninstall any previous version of Ansys prior to installing ​v13.0 as Ansys v13.0 Workbench will not function otherwise.+Due to the size of the installation,​ please DO NOT attempt to install this application via a wireless or VPN network connection. ​ Prior to installing any new version or upgrade, please ensure that you are connected to a live, wired, Ethernet jack on campus and that your wireless network interface is disabled. You will need to uninstall any previous version of Ansys prior to installing ​v18 as Ansys v18 Workbench will not function otherwise.
  
-===== Installing Ansys Multiphysics ​13.0 ===== +===== Installing Ansys Multiphysics ​18 ===== 
-  - IE users may click to follow the link, for any other browser you will need copy & paste the link into a Run…” ​dialog window or  +  - IE users may click to follow the link, for any other browser you will need copy & paste the link into a **Run...** dialog window or the Windows Start Menu search box. 
-the Windows ​Start Menu search box. +    - [[\\fsvs01\Applications\Public\netapps\Ansys\18.0\windows\disk1]] 
-    - 32-bit users should browse to the following folder:  ​\\stuapp\netapps\Ansys\v13.0\x32\dvd1 +    - Right click **InstallPreReqs.exe** and select ​**Run as Administrator** 
-    - 64-bit users should browse to the following folder: ​ \\stuapp\netapps\Ansys\v13.0\x64\dvd1 +    - If you receive a Security Warning window, click **Run** to continue the install. ​ Allow all of the required prerequisite programs to install normally. ​ Click **Run** in any following security windows. ​ This should require minimal user interaction 
-    - Right click InstallPreReqs.exe and select ​Run as Administrator +  - Following the prerequisite program installations,​ right click on setup.exe and select ​**Run as Administrator** 
-    - If you receive a Security Warning window, click Run to continue the install. ​ Allow all of the required prerequisite programs to install normally. ​ Click Run in any following security windows. ​ This should require minimal user interaction +    - If you receive a Security Warning window, click **Run** to continue the install. 
-  - Following the prerequisite program installations,​ right click on setup.exe and select ​Run as Administrator +  - Click **Install ANSYS Products** 
-    - If you receive a Security Warning window, click Run to continue the install. +  - Select ​**I Agree** in the License Agreement window to accept the license agreement 
-  - Click Install ANSYS, Inc. Products +    - Click the arrow on the right side of the window. ​ For the rest of this install ​guidethis will be refrenced to as clicking Next
-  - Select ​I Agree” in the License Agreement window to accept the license agreement +  - Click **Next** to accept default installation path.
-    - Click Next +
-  - If prompted for platform to install, ​select your platform ​(“Windows 32” vs. “Windows 64”) +
-  - Click Next to accept default installation path.+
     - You may choose to disable the ANSYS RSS feed if you wish.     - You may choose to disable the ANSYS RSS feed if you wish.
-  - In the Select Installation Components window, accept the defaults and click Next to continue. +  ​- The Enter License Server Specification window should appear next 
-    - If you have Pro/E or any of the other programs that Ansys can interface with, make sure to check the box next to those products so that the appropriate files will be installed. ​ These may already be appropriately marked for you. +    - If you had a previous version of ANSYS installed you may not receive this window. ​ If it doesn, please ensure it matches the following:​ 
-  - If you have Pro/E installed, enter the path to your ProE installation and click Next. +   - ANSYS Licensing Interconnect port number (default is 2325): ​ ''​2325''​ 
-    - If you do not have Pro/E installed select ​Skip this step for ICEM and configure later” and click Next to continue.  +      - ANSYS FLEXlm port number (default is 1055): ​ ''​1400''​ 
-  - Accept the defaults for the Unigraphics NX installation if prompted; click Next. +      - Select number of license server machines: ​ 1-server 
-    - Skip this step for ICEM and configure later” should be checked for you.  If not, check it and click Next to continue.  +      - Hostname 1:  ''​NETAPP01.olin.edu''​ 
-  - The installer will now verify ​the license manager file dates.  ​ +  ​- In the Select Installation Components window, accept the defaults and click **Next** to continue. 
-    Click Next after verification has completed. +    - If you have Creo (formerly ​Pro/Eor any of the other programs that Ansys can interface with, make sure to check the box next to those products so that the appropriate files will be installed. ​ These may already be appropriately marked for you. 
-  - Click Next at the review screen to begin installation. ​  +  - If you have Creo installed, enter the path to your ProE installation and click **Next**
-    - At first it may install any missing prerequisites that ANSYS needs to run.  If you quickly receive a message that Everything was successfully installed,” do not close out of the installation window.+    - If you do not have Creo installed select ​**Skip this step for ICEM and configure later** and click **Next** to continue.  
 +  - Accept the defaults for the Unigraphics NX installation if prompted; click **Next**
 +    - **Skip this step for ICEM CFD and configure later** and **Skip this step for Workbench and configure later** ​should be checked for you.  If not, check it and click **Next** to continue.  
 +  - Accept ​the defualts for SolidWorks; click **Next** 
 +  Accept the defualts for Autodesk Inventor; click **Next** 
 +  - Click **Next** at the review screen to begin installation. ​  ​ 
 +    - At first it may install any missing prerequisites that ANSYS needs to run.  If you quickly receive a message that **Everything was successfully installed,** do not close out of the installation window.
     - This installation can take a very long time.  The window may appear to freeze during the installation or not give any indication that the install has started immediately.     - This installation can take a very long time.  The window may appear to freeze during the installation or not give any indication that the install has started immediately.
   - When prompted for the path to DVD to copy and paste the following into the dialog box:   - When prompted for the path to DVD to copy and paste the following into the dialog box:
-    - 32-bit users:  ​\\stuapp\netapps\Ansys\v13.0\x32\dvd2 +    - [[\\fsvs01\Applications\Public\netapps\Ansys\18.0\windows\disk2]] 
-    - 64-bit users:  ​\\stuapp\netapps\Ansys\v13.0\x64\dvd2 +   You may also select **Browse** and travel up one directory and select the disk2 folder 
-  - Click Next after the installation has completed. ​ +  - Click **OK** 
-  - The license file will configure some settings, the “Specify the License Server Machine” window may popup. +  - Click **Next** after the installation has completed.  
-    - If you had a previous version of ANSYS installed you may not receive this window +  - Click **Next** at the Finish Installation screen. 
-  - If there is already an ANSYS Flexlm server specified, click exit.  If there is no machine specified, ensure that your licensing info matches the following:​ +  - You may be prompted to answer survey questions, ​uncheck this box before selecting Exit if you do not want to do so
-    - ANSYS Licensing Interconnect port number (default is 2325): ​ 2325 +  - Click **Exit** in the installation manager.
-    - ANSYS FLEXlm port number (default is 1055): ​ 1400 +
-    - Select number of license server machines: ​ 1-server +
-    - Hostname 1:  STUAPP +
-  - Click Exit at the Licensing Client Installation Configuration Screen +
-  - Click Next at the Finish Installation screen. +
-  - You may be prompted to answer survey questions, ​click Finish ​to skip or click Next to answer the questions+
-  - Click Exit in the installation manager. +
-  - Load ANSYS Workbench. ​ Select: Tools > License Preferences… +
-  - Under “Global Settings” select “Use Academic Licenses” if it is not already selected, click Apply, click OK +
-    - You will need to restart ANSYS Workbench for the changes to take effect. +